Topica Loopframe_Guzzi Archive


Subject: Re: cold bank

Author: Ian Adkins

Date: Apr 30, 2001, 9:00 PM

Post ID: 1706538120


Bob,

There should be two terminals on the generator. I believe if you look on the
back of the generator you will see a "DF" or "D+" on one of the terminals.

There will actually be three wires coming from the generator. The grey-red
wire runs to the "D+" terminal on the Voltage Regulator. From the same
terminal a red wire will run to the warning lamp on your speedo housing.

A white wire will run from the "DF" terminal to the voltage regulator.

Regards....Ian


-----Original Message-----
From: Robert Hawkes <haw-@frontiernet.net>
To: Loopfram-@topica.com <Loopfram-@topica.com>
Date: April 30, 2001 9:54 PM
Subject: Re: cold bank


 
Tim,
Just was looking at the generator on my Ambo tonight. I noticed two wires
hooked up to the generator but the two wires are connected to the same
contact. It that correct? I should think each wire would get connected to
it's own contact. Just curious, Bob