Topica Loopframe_Guzzi Archive


Subject: RE: Generator

Author: Jesse Open

Date: Dec 1, 2002, 3:03 PM

Post ID: 1711496873


Joe, you didn't say whether the discharge was while the engine was
running or off. If you are getting a discharge while the engine is shut
down and the ignition is off a sticky contact in the regulator is the
culprit. If the generator is not charging and the field is getting
excitation voltage ,yes the generator could be discharging the battery
when running but you have other current draws as well.
Joe Polselli wrote:
 Hello is it possible for the generator to drain versus charge the
battery.



1969 V700 Euro
1977 T-3 LAPD for sale or trade for Cal II
1993 Cal III Fuel Injection FOR SALE!

http://www.picturetrail.com/gallery/view?p=999&gid=1019192&uid=636945&membe

Entire thread: