Topica Loopframe_Guzzi Archive


Subject: Re: Gen Warning Light

Author: Ian Adkins

Date: May 10, 2001, 7:13 PM

Post ID: 1706676178


Ed,

Set the screws out 1 1/2 turns to start. Adjust accordingly after
that...idle first then mixture.

Regards...Ian

-----Original Message-----
From: Edward Flanagan <flan-@edwardsbaking.com>
To: 'Loopfram-@topica.com' <Loopfram-@topica.com>
Date: May 10, 2001 1:33 PM
Subject: RE: Gen Warning Light


I had this happen to me when I noticed that my generator belt had too much
slack in it and was slipping on the pulley. As I remember it when the belt
finally broke on the road, the light stayed on until I replaced the belt. On
a separate note, does anyone know of the correct settings for the Mixture
screws and the throttle slide screws on the VHB carbs. They were apart when
I got them and I need to set them up initially until I can adjust.

Thanks, Ed