Topica Loopframe_Guzzi Archive


Subject: RE: Getting rid of the Bosch Regulator?

Author: Greg Bender

Date: Apr 23, 2005, 12:41 PM

Post ID: 1718749703



Hi Tom,

Yes, with the alternator conversion, you can completely eliminate the
stock regulator. And, yes, just run the cable directly from the battery
to the starter.

Tom Christian wrote:
 
I put Greg Fields alternator conversion on the Eldo, and
it appears to be charging the battery (14.5v), but after a
long ride the battery was in fact, quite dead (9v). Had
the battery tested - its fine. The other symptom is the
alt/formerly generator light is not lighting (no its not
the bulb, when I ground the wire to it with the switch on,
it lights).

I'm wondering if I could have a sketchy regulator. Greg's
instructions are quite clear on which wires to remove and
which to leave - the one supply positive to the regulator
directly from the battery, and the one supplying power to
starter relay from the regulator. Is there any reason I
can't just remove the regulator and supply power to the
starter relay directly from the battery?

-tom



Regards,

Greg Bender
1971 Ambassador
2000 Quota
http://www.thisoldtractor.com/gtbender

Florida MGNOC website
http://www.thisoldtractor.com/fl_mgnoc

Minnesota MGNOC website
http://www.thisoldtractor.com/mn_mgnoc

Entire thread: